• Insulation Flange
  • Insulation Flange

Insulation Flange

Brand :YY

Product origin :LIAONING,CHINA

Delivery time :60 days

Supply capacity :200 sets per month

Insulating joint (Isolating Joint) is the key component in Cathodic Protection (CP) System. It is mainly used in underground gas transition and distribution system including gas reducing station, each section of gas transition and distribution pipeline, also the part between gas reducing station and the pipeline, which increase the life of the plant and equipment by reducing or eliminating the electric and chemical corrosion damage.

Monolithic Insulating joint

  • Size: 1''-120'',CL150, CL200, CL300, CL400, CL600, CL900, CL1500, CL2500

  • Standard: GB150-2011 or ASME B 31.8 or ASME B 31.4/31.3

  • Installation place: Aboveground or underground

  • Business Type: Manufacturer

Insulation Flange

Materials characteristics

Specifications:

 Suitable for oil, city gas, nature gas, LNG, LPG, etc.

 Size:  1” to 120”

 Matching pipeline: API 5L Gr. B, X42, X52, X60, X65, X70, etc.

 Pressure rating:  ANSI Class 150, Class 300, Class600, Class 900, Class1500, Class2500

 Ambient Temperature: -30°C-90°C

 Working Temperature: --20°C-120°C

 Assembled parts: According to ASTM A694  F52/JB4726:16Mn Ⅱ(pressure grade<6.4MPa) 16Mn Ⅲ(pressure grade≥6.4MPa)

Short tube: equivalent to that of pipeline

Insulating material:ASTM D709 G11 or GB1301.1-1998 high strength epoxy glass cloth laminated material

Filling material: high strength epoxy resin

Sealing material: rubber fluoride

Sealing stickiness: silicon rubber

Surface anti-corrosion insulating material: two-component solvent-free epoxy coating, anti-corrosion thermal contraction bushing

Standard Testing: 

 Hydrostatic test: 1.5 times MOP (Max. Operation Pressure).

 Electrical Resistance:  >= 20Mohm @ 1000v DC under dry air at 25 oC

 Dielectrical voltage:  >= 3.5kv AC 50Hz (1 minute) (Can be 5kv as per request)

Ordering Information:

Please specify the following requirement:

Pipeline Diameter, Grade of pipe, wall thickness of pipe;

ANSI rating Medium to be transported in pipeline and temperature of transported medium Additional Testing required except standard testing: X-ray, ultrasonic & magnetic testing, etc.

Insulation Flange


Insulation Flange


After-sales service

We promise that:

We answer and solve your questions and consult within 24 hours.

We arrive to the domestic job site within 48 hours from the time you asked.

Overseas job site service available.

Service telephone: +86-24-88256563

Factory Show

Our Factory
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right